We believe every interaction with our customer is an opportunity!

Make An Enquiry
Logo

Location E-Mail ID

instrumentsindia6@gmail.com, info@instrumentsindia.in

phoneCustomer Support

+91-9818136746

  • Home
  • About Us
  • Products
    • Raman Spectrometer
    • Surface Tension
    • Lb Trough
    • Brewster Angle Microscope
    • Atomic Force Microscope
    • Nanoparticle Sized Analyser
    • Contact Angle
    • Gc
    • Metal Nano Powder Generator
  • Enquiry
  • Contact

 

 

  1. Home
  2. Raman Spectrometer
  3. Protrustech Raman Systems - Mrid Dual-laser Autoscan

Protrustech Raman Systems - Mrid Dual-laser Autoscan

Categories

  • Raman Spectrometer
  • Surface Tension
  • Lb Trough
  • Brewster Angle Microscope
  • Atomic Force Microscope
  • Nanoparticle Sized Analyser
  • Contact Angle
  • Gc
  • Metal Nano Powder Generator

Description

Specification

MRID Dual-Laser Raman

2 Scans in 1 Click

 

MRID Raman Microscope

 

MRID is a microscopic Raman identification system built in with two lasers that could instantly switch by software or automatically switch between scans at different wavelengths.   This patented laser auto switch technology allows users without expertise to switch lasers any time immediately while still ensuring that the optical path for each laser stays optimised after every switch. MRID makes it unprecedentedly easy to swiftly inspect the same sample right at the same spot with any two different laser wavelengths among 473, 488, 532, 633, 785, 808 and 830 nm. Moreover, the two excitation sources could also be applied at the same time.

 

 

 

MRID 532/785 Dual Lasers - Scans with Auto Switch

 

 

Raman & PL in One Click 

One-click to get both Raman and Photoluminescence spectra. MRID could be equipped with an excitation source for Raman spectroscopy while the other for Photoluminescence (eg. 375 or 405 nm). With the auto switch technology, both Raman and PL scans could be completed one after another automatically with one single click.

 

0.01 mW/step Laser Power Control 

Direct laser output could be controlled at 1mW/step by software, plus a round continuously variable neutral density filter (O.D 2.0~0.04) contolled by software offering transmission from 1% to 100%, resulting in 0.01 mW/step laser power control.

 

Advanced Features 

 

Motorised Stage

 

MRID Mapping Intensity

Mapping - Intensity

 

MRID Mapping FWHM

Mapping - FWHM

 

Polarisation Mode

 

InSe Polarised Spectra

InSe Polarised Spectra

XX: peaks ~116 cm-1, 226 cm-1 

XY: peak at ~177 cm-1

 

 

Polarised Module

Laser incident angle adjustable by the polariser module.

 

 

Cooling & Heating

MRID temperature stage

Heating Stage : 1500 K

 

MRID cooling stage 4K

Cooling Stage : 4 K / 77 K

  

Smart Raman System

Smart features keep you out of all the troubles - Laser power could be adjusted by 5 steps via ND filters as well as by 100 steps thru software control. Laser modules could be adjusted and optimised in 3 directions. Over-exposure caused by the laser beam is prevented under microscopic imaging. Laser auto sleep mode. Restorable laser parameters. Programmable batch scans, and so on and so forth.

 

Intelligent Imaging

 

Laser Spot

Microscopic image by other brands

 

Laser spot PTT

  PTT: automatically compensated exposure 

 

Software

 

RAMSpec Camera

RAMSpec & digital microscopic imaging

 

MRID motorised stage mapping

RAMSpec Pro & Raman mapping feature

 

Customised Chamber 

MRID Enclosed Chamber

Laser safety and noise reduction

Objective Lenses

  • 10X, WD= 6.5 mm, NA = 0.25
  • 50X, WD= 8.2 mm, NA = 0.55
  • Optional: 2X, 20X, 40X, 100X, Long WD.

 

Optical Box Dimensions

  • MRID: 300 x 300 x 80 mm ( W x D x H )
  • MRI+: 195 x 130 x 195 mm ( W x D x H )

 

Laser Power Control

  • ND filter: 1% / 5% / 10% / 25% / 100%
  • Software control: 1 mW per step

 

Sensitivity

  • 470,000 in counts/μW per ms integration time

 

Detector

  • TE cooled, -50 °C to -100 °C; UV/NIR enhanced coating
  • Active pixels: 1650 x 200, 1024 x 255
  • Slit range: 10 μm ~ 2.5, 3 or 15 mm. Manual or software control
  • Grating: 300, 600, 1200, 1800, 2400, 3600 gr/mm. Software control

 

Control & analysis software

  • Standard: RAMSpec
  • Optional: RAMSpec Pro

 

Options

 

Mapping XY Stage

 

  • Motorised XY Stage with RAMSpec Pro Software
  • Scan XY: min. 50 nm / step
  • Travel Range XY: 3" X 2" (76m X 52 mm)
  • Repeatability: < 1 μm
  • Accuracy: ± 3 μm

 

Mapping XYZ Stage

  • Motorised XY Stage with RAMSpec Pro Software
  • Scan XY: min. 50 nm / step
  • Scan Z: min. 20 nm / step
  • Travel Range XY: 3" X 2" (76m X 52 mm)
  • Repeatability: < 1 μm
  • Accuracy: ± 3 μm

 

Polariser Module / Basic

  • SM05-mounted linear polariser set
  • Zero-order half-wave plate set
  • Rotation mount set

 

Polariser Module

  • SM06-mounted linear polariser set
  • Zero-order half-wave plate set
  • Unmounted linear polariser set
  • Achromatic half-wave plate set
  • Rotation mount set

 

Enclosed Chambber

  • Laser off upon door opening

 

eFTIR

  • Database matching software

 

 

Laser Modules

Select any two (2) laser modules from below for your MRID system. The 1064-nm laser has to stand alone. Select one (1) excitation source for your MRI+ system.

 

375 nm PL

  • 75 mW, TEM00 / CW mode
  • PL Range: 385 ~ 1100 nm

 

405 nm PL

  • 125 mW, TEM00 / CW mode
  • PL Range: 415 ~ 1100 nm

 

473 nm Raman

  • 100 mW, TEM00 / CW mode
  • Raman Shift: 150 ~ 3000 cm-1 | Resolution: 1.8 cm-1

 

488 nm Raman

  • 75 mW, TEM00 / CW mode
  • Raman Shift: 290 ~ 3000 cm-1 | Resolution: 1.8 cm-1

 

532 nm Raman

  • 125 mW, TEM00 / CW mode
  • (a) Raman Shift: 79 ~ 2100 cm-1 | Resolution: 1.3 cm-1
  • (b) Raman Shift: 79 ~ 3500 cm-1 | Resolution: 1.8 cm-1

 

633 nm Raman

  • 75 mW, TEM00 / CW mode
  • Raman Shift: 160 ~ 3000 cm-1 | Resolution: 1.9 cm-1

 

785 nm Raman

  • 250 mW, TEM00 / CW mode
  • Raman Shift: 150 ~ 3500 cm-1 | Resolution: 1.8 cm-1

 

808 nm Raman

  • 125 mW, TEM00 / CW mode
  • Raman Shift: 150 ~ 3200 cm-1 | Resolution: 1.5 cm-1

 

830 nm Raman

  • 125 mW, TEM00 / CW mode
  • Raman Shift: 150 ~ 3200 cm-1 | Resolution: 1.5 cm-1

 

1064 nm on request

 

* Each module includes the excitation source, optical module and spectrometer.

* Beam diameter: ~ 1.1 x 2.2 mm / round beam ~ 1.2 mm for 532 nm laser.

 

Loactaion

Address

B-203, PKT-12, 1st Floor, DDA Flats LIG, Jasola Vihar, New Delhi-110025, Delhi, India

Phone

Phone

+91-9818136746,
+91-8810364734

Email

Email Id

instrumentsindia6@gmail.com
info@instrumentsindia.in

Logo

Instruments India started in the years 2009 as Sole Proprietor, are one of the foremost dealing with various  Scientific Instruments  for Laboratories and many more. 

Our Products

  • Raman Spectrometer
  • Surface Tension
  • Lb Trough
  • Brewster Angle Microscope
  • Atomic Force Microscope
  • Nanoparticle Sized Analyser
  • Contact Angle
  • Gc
  • Metal Nano Powder Generator

Newsletter

Subscribe to our email newsletter to receive updates and news.

Stay Connected

Copyright © 2021 Instruments India - All Right Reserved.